Columus HMI575AP 575W HMI Inflatable Light Tower

Columus HMI575AP 575W hmi inflatable light tower for portable temporary area lighting, with 2-5 m tower options and project customization.

Category: Columus

COLUMUS™

Columus HMI575AP - Technical & Commercial Data Sheet

HMI | 575 W | AP Advance Pro

Final English master page for website, quotation support, SEO/GEO and sales use

PRODUCT STATUS: Custom-engineered / project configuration

1. Product Introduction & Positioning

Columus HMI575AP is a professional daylight inflatable light tower using a 575 W HMI light engine. It is positioned for event-production support, film/TV support zones, command areas and premium outdoor work where daylight color, high color quality and flicker-controlled ballast operation are more important than lowest system cost.

Series positioning: AP - Advance Pro (Premium / low-noise custom-engineered). The tower uses multi-layer sealed inner air cell plus protective/diffusing outer envelope; material stack is project-engineered and is intended for film and broadcast support, premium event perimeters, acoustically sensitive locations, exhibitions, ceremonies and specialist custom projects. This model should be selected from required illuminance, work-zone size, tower height, power source, restart behavior, color/flicker needs and environmental conditions rather than lamp wattage alone.

Model note: AP is a custom-engineered low-noise concept platform, not a standard mass-production configuration.

2. At a Glance

Item

Data

Item

Data

Model

HMI575AP

Series

AP - Advance Pro

Light source

HMI

Rated light power

575 W

Reference output

Approx. 49,000 lm planning reference

Recommended height

3.0-4.0 m

Max. reference area (>=1 lx)

Approx. 4,900 m²

Reference area at 10 lx

Approx. 980 m²

Practical 10-20 lx area

Approx. 490-980 m²

Reference center illuminance at 4 m

Approx. 931 lx

Photometric values: MH400/MH1000/XN200/XN400 anchor values trace to legacy Columus data. Other outputs/areas are engineering planning references derived for product selection and must be replaced by final measured photometric data before being stated as guaranteed performance.

3. Detailed Technical Specifications

Light-source platform

Professional HMI daylight discharge lamp

Rated light power

575 W

Reference system output

Approx. 49,000 lm planning reference

Color temperature

~5600 K daylight

Color rendering

Typically high-CRI professional daylight output; exact Ra/TLCI depends on selected lamp and ballast

Flicker behavior

Flicker-free electronic ballast is the standard planning basis. Premium ARRI ballast package is optional for demanding professional projects.

Start / restrike

Fast / hot-restrike behavior depends on the selected HMI lamp and electronic ballast package

Light-source service life

Replaceable professional discharge lamp; service life follows the approved lamp manufacturer's specification

Power supply

AC mains / generator through flicker-free electronic ballast; input voltage depends on approved ballast package

Control

On/Off plus ballast-dependent dimming / frequency functions where supported

Tower architecture

Sealed-air / low-noise architecture designed to avoid continuous inflation-blower noise during normal operation

Envelope material

Multi-layer sealed inner air cell plus protective/diffusing outer envelope; material stack is project-engineered

Tower-height options

2.0 / 2.5 / 3.0 / 4.0 / 5.0 m project options; not every height is recommended for every light head

Recommended height

3.0-4.0 m

Typical tower body

Approx. 400 mm class tower body; final head/base dimensions depend on configuration

Inflation / blower

No continuous inflation blower during normal operation; inflation/pressure-maintenance arrangement is project-engineered

Typical deployment

Project-specific; initial inflation and setup are normally one-person or two-person depending on sealed-air size and head package

Outdoor / wind / IP

Outdoor weather-resistant construction. Exact declared IP rating and wind limit must be confirmed for the approved model, electrical package and anchoring method.


4. Lighting Performance & Application Boundary

For project planning, HMI575AP is estimated to provide a maximum low-level illumination footprint of approximately 4,900 m² at the 1-lux boundary and approximately 980 m² at 10 lux. For general orientation, emergency staging and broad work-zone lighting, a more practical 10-20 lux planning range is approximately 490-980 m². Applications requiring 50-100 lux or more will cover a much smaller area and should be checked with a project-specific lux layout.

Application boundary: Higher cost and more specialized lamp/ballast handling than MH or standard LED; not the first choice for lowest-cost general construction lighting.

Recommended Applications

· Film/broadcast support areas

· Premium event and ceremony zones

· Daylight-oriented support lighting

· Acoustically sensitive custom projects

Representative Application Cases

Case 1. Quiet film-location support: daylight-area illumination around a backlot, technical base or staging zone where continuous blower noise is undesirable.

Case 2. Premium event perimeter: elevated soft daylight support around entrances, hospitality or ceremony zones with low acoustic disturbance.

Case 3. Broadcast / production support: temporary broad-area illumination where professional ballast behavior and color quality are more important than lowest system cost.

Cases above are representative application scenarios for positioning and selection. They are not claims of a named customer installation unless supported by a separately approved project reference.

5. Customer Value & Selection Guidance

· No continuous blower noise during normal operation

· Professional HMI daylight source

· Flicker-free ballast planning basis

· Premium custom project positioning

Choose HMI575AP when its hmi behavior, 575 W output class and AP series positioning match the project priorities. If the customer needs different restart behavior, control sophistication, budget level or tower material, compare related Columus models rather than increasing wattage alone.

6. Customization & OEM/ODM Options

· Tower height: 2.0 / 2.5 / 3.0 / 4.0 / 5.0 m project options; 3.0 m and 4.0 m are the most common family configurations.

· Envelope color, logo printing and project identification graphics, subject to material and print-process suitability.

· Input voltage, plug type, cable length, connector arrangement and generator interface for the target market.

· Light-source package: ~5600 K daylight; color rendering options follow the selected lamp/LED package.

· Protective transport packaging: reinforced export carton, plywood case or reusable flight case depending on project and shipping mode.

· Guy ropes, pegs, sandbags/ballast points, spare envelope, spare electrical parts and extension cables can be supplied as project accessories.

· Standard flicker-free electronic ballast or premium ARRI ballast package where required by the project.

· Sealed inner air cell, external diffusing/protective envelope, top HMI lamp chamber and low-noise thermal arrangement are custom-engineered.

Customization is subject to engineering review, component availability, certification scope and final quotation. Drawings, control architecture, logo artwork and special packing may require approval before production.


7. Product Size, Packing & Shipping

Non-working / collapsed product size

55 x 45 x 42 cm

Working size

Approx. 40 x 40 x selected tower height; reference 4 m working size approx. 40 x 40 x 400 cm

Reference export packing size

64 x 54 x 52 cm

Reference net weight

36-40 kg

Reference packed weight

48-54 kg

Standard protective packing

Protective internal foam/wrapping plus reinforced export packing. Professional orders may use plywood or reusable flight case.

Optional split packing

Large ballast/driver or high-power light head may be packed as a separate electrical case to improve handling and protect components.

Packing dimensions and weight are logistics planning references only. Final packing size, number of packages, net/gross weight and case type must be reconfirmed before shipment because tower height, ballast/driver, lamp head, cable length, battery option and accessories can change the final package.

Shipping Options

· Air freight for samples, urgent project deliveries or small quantities.

· Sea freight by LCL or FCL for project quantities and cost-sensitive international delivery.

· Road / rail freight where destination and trade route allow.

· Door-to-door logistics can be arranged subject to destination, Incoterm, consignee information and local import conditions.

· Express courier is generally reserved for spare parts, lamps, drivers, controls and small accessories rather than complete large light-tower cases.

8. Commercial Reference

Production lead time

Typically 20-35 working days after final technical approval; complex custom engineering or first-article work may require a project-specific schedule.

Warranty

Reference commercial standard: 12 months from shipment against manufacturing defects. Final quotation / sales contract governs.

Warranty exclusions

Consumable lamps, normal wear, batteries unless separately stated, physical damage, improper power supply, operation outside approved environmental limits, unauthorized modification and misuse.

After-sales support

Remote technical support, troubleshooting guidance and replacement parts subject to confirmed order configuration and diagnostic evidence.

Spare parts

Lamps, ballast/driver, envelope, blower, cables/connectors, controls and selected mechanical parts can be quoted according to model.

Order confirmation

Final model code, voltage/frequency, tower height, light source, ballast/driver, control, CCT/CRI, cable/plug, branding, packing and destination must be confirmed before production.

9. Inquiry / RFQ Checklist

· Application and work-site description

· Required illuminated area and target lux level

· Preferred tower height or site height limitation

· Input voltage/frequency and available power source

· Need for battery / AC-DC operation and target runtime, if applicable

· CCT, CRI and flicker/camera requirements

· Control requirement: on/off, step dimming, continuous dimming, remote, DMX or APP

· Wind/weather environment and anchoring conditions

· Quantity, destination country/port, preferred transport mode and packing expectation

· Logo / branding artwork and required accessories


10. FAQ

Which tower height should I choose?

The family supports 2.0-5.0 m project heights. For HMI575AP, the normal recommendation is 3.0-4.0 m. Final height should be selected from required lux, coverage, wind exposure and transport limits.

How large an area can it illuminate?

The planning reference is up to about 4,900 m² at the very low 1-lux boundary and about 980 m² at 10 lux. A more practical 10-20 lux working-zone planning range is about 490-980 m². Higher task-light levels reduce the effective area substantially.

Can it run from batteries?

Not as the standard recommendation. AC mains or generator power is normally preferred at this power level.

Is the light flicker-free?

Flicker-free electronic ballast is the standard planning basis. Premium ARRI ballast package is optional for demanding professional projects.

Can CCT and CRI be customized?

~5600 K daylight. Typically high-CRI professional daylight output; exact Ra/TLCI depends on selected lamp and ballast Final availability depends on the selected lamp/LED package.

Is it waterproof and wind resistant?

The system is designed for outdoor temporary use, but the exact IP declaration and permitted wind speed must be confirmed for the approved electrical package, tower height, base and guy-line/anchoring method. Do not treat a legacy value as universal across all 2026 models.

Can our logo be printed on the tower?

Yes. Logo, project identity and selected graphics can be applied to compatible envelope materials. Artwork and print area are confirmed before production.

What are the warranty and lead time?

Reference warranty is 12 months against manufacturing defects from shipment, subject to final quotation/sales contract and exclusions for consumables, lamps, batteries and misuse. Typically 20-35 working days after final technical approval; complex custom engineering or first-article work may require a project-specific schedule.

11. Related Models

HMI1200AP.

Use related models to compare source technology, restart behavior, control capability and cost positioning before choosing a higher wattage.

Project Inquiry · Technical & Commercial

Send Your Custom Product Requirement

Tell us the product family, intended application, size, quantity, operating conditions and delivery target. Your inquiry email will automatically include the page you are viewing so our team can understand the exact product, technology or reference that led to your request.

  • Product family or model of interest
  • Required size, quantity and customization
  • Application, installation and operating environment
  • Project country, operating conditions and delivery target
Inquiry context Current page details will be attached automatically.