Fenigal Btcoops - Specialized Balloon Light, Inflatables, Electricals, Equipment and Tools
Fenigal Btcoops - Specialized Balloon Light, Inflatables, Electricals, Equipment and Tools
Translate this website

Google Translate is loaded only when you open this panel, reducing unnecessary requests and layout work during the first page load.

Loading language options…
Request Quote

Columus

Professional Product Detail

Columus SMD400SP 400W AC SMD Inflatable Light Tower

Columus SMD400SP 400W ac smd inflatable light tower for portable temporary area lighting, with 2-5 m tower options and project customization.

Category: Columus

COLUMUS™

Columus SMD400SP - Technical & Commercial Data Sheet

LED - AC SMD | 400 W | SP Standard Pro

Final English master page for website, quotation support, SEO/GEO and sales use

PRODUCT STATUS: Standard product architecture with model-specific engineering confirmation

1. Product Introduction & Positioning

Columus SMD400SP is a cost-efficient direct-AC SMD LED inflatable light tower designed around a simplified electrical architecture. The LED board is installed in the lighting head and normally operates directly from AC power, reducing component count and cost while retaining instant start and optional two-step power switching.

Series positioning: SP - Standard Pro (Professional / upper-standard). The tower uses premium translucent flame-retardant, uv-resistant composite envelope and is intended for industrial night work, emergency response, rescue, infrastructure, mining, ports, airports, professional event support and film/TV support zones. This model should be selected from required illuminance, work-zone size, tower height, power source, restart behavior, color/flicker needs and environmental conditions rather than lamp wattage alone.

2. At a Glance

Item

Data

Item

Data

Model

SMD400SP

Series

SP - Standard Pro

Light source

LED - AC SMD

Rated light power

400 W

Reference output

44,000-56,000 lm design target

Recommended height

3.0-4.0 m

Max. reference area (>=1 lx)

Approx. 5,000 m²

Reference area at 10 lx

Approx. 1,000 m²

Practical 10-20 lx area

Approx. 500-1,000 m²

Reference center illuminance at 4 m

Approx. 950 lx

Photometric values: MH400/MH1000/XN200/XN400 anchor values trace to legacy Columus data. Other outputs/areas are engineering planning references derived for product selection and must be replaced by final measured photometric data before being stated as guaranteed performance.

3. Detailed Technical Specifications

Light-source platform

Direct-AC SMD LED board

Rated light power

400 W

Reference system output

44,000-56,000 lm design target

Color temperature

5000-6500 K standard planning range; other CCT options subject to board availability

Color rendering

Typically Ra >=80 for professional configurations; entry versions may use Ra 70-80 boards. Higher-CRI options are project-dependent.

Flicker behavior

Direct-AC boards may exhibit mains-frequency flicker. Not recommended for high-speed filming unless a verified low-flicker board architecture is specifically selected.

Start / restrike

Instant

Light-source service life

LED board life is thermal-design and component dependent; approved board specification governs

Power supply

AC mains / generator, typically 120 V or 220-240 V AC, 50/60 Hz subject to approved board

Control

On/Off standard; optional two-step switching 200 W / 400 W

Tower architecture

Continuous-air inflatable tower with integrated low-power blower

Envelope material

Premium translucent flame-retardant, UV-resistant composite envelope

Tower-height options

2.0 / 2.5 / 3.0 / 4.0 / 5.0 m project options; not every height is recommended for every light head

Recommended height

3.0-4.0 m

Typical tower body

Approx. 400 mm class tower body; final head/base dimensions depend on configuration

Inflation / blower

Continuous-running blower typically 80-150 W depending on tower height and light-head mass

Typical deployment

Typically 2-5 minutes by one trained operator, depending on packing, anchoring and guy-line arrangement

Outdoor / wind / IP

Outdoor weather-resistant construction. Exact declared IP rating and wind limit must be confirmed for the approved model, electrical package and anchoring method.


4. Lighting Performance & Application Boundary

For project planning, SMD400SP is estimated to provide a maximum low-level illumination footprint of approximately 5,000 m² at the 1-lux boundary and approximately 1,000 m² at 10 lux. For general orientation, emergency staging and broad work-zone lighting, a more practical 10-20 lux planning range is approximately 500-1,000 m². Applications requiring 50-100 lux or more will cover a much smaller area and should be checked with a project-specific lux layout.

Application boundary: Best where simplified construction and lower cost are more important than advanced dimming, DMX or camera-grade flicker performance.

Recommended Applications

· Construction and roadwork

· Rental fleets and local contractors

· General outdoor temporary area lighting

· Budget-sensitive industrial or municipal work

Representative Application Cases

Case 1. Construction and road work where simple AC operation and low component count are priorities.

Case 2. Rental fleet or local contractor use requiring fast deployment and straightforward on/off operation.

Case 3. General outdoor temporary lighting where advanced DMX or camera-grade flicker performance is not required.

Cases above are representative application scenarios for positioning and selection. They are not claims of a named customer installation unless supported by a separately approved project reference.

5. Customer Value & Selection Guidance

· Instant start

· Simplified direct-AC architecture

· Lower BOM and cost

· Optional two-step power switching

Choose SMD400SP when its led - ac smd behavior, 400 W output class and SP series positioning match the project priorities. If the customer needs different restart behavior, control sophistication, budget level or tower material, compare related Columus models rather than increasing wattage alone.

6. Customization & OEM/ODM Options

· Tower height: 2.0 / 2.5 / 3.0 / 4.0 / 5.0 m project options; 3.0 m and 4.0 m are the most common family configurations.

· Envelope color, logo printing and project identification graphics, subject to material and print-process suitability.

· Input voltage, plug type, cable length, connector arrangement and generator interface for the target market.

· Light-source package: 5000-6500 K standard planning range; other CCT options subject to board availability; color rendering options follow the selected lamp/LED package.

· Protective transport packaging: reinforced export carton, plywood case or reusable flight case depending on project and shipping mode.

· Guy ropes, pegs, sandbags/ballast points, spare envelope, spare electrical parts and extension cables can be supplied as project accessories.

· Optional two-step power switching according to the approved board and model.

Customization is subject to engineering review, component availability, certification scope and final quotation. Drawings, control architecture, logo artwork and special packing may require approval before production.


7. Product Size, Packing & Shipping

Non-working / collapsed product size

50 x 40 x 35 cm

Working size

Approx. 40 x 40 x selected tower height; reference 4 m working size approx. 40 x 40 x 400 cm

Reference export packing size

58 x 48 x 45 cm

Reference net weight

28-31 kg

Reference packed weight

38-42 kg

Standard protective packing

Protective internal foam/wrapping plus reinforced export packing. Professional orders may use plywood or reusable flight case.

Optional split packing

Large ballast/driver or high-power light head may be packed as a separate electrical case to improve handling and protect components.

Packing dimensions and weight are logistics planning references only. Final packing size, number of packages, net/gross weight and case type must be reconfirmed before shipment because tower height, ballast/driver, lamp head, cable length, battery option and accessories can change the final package.

Shipping Options

· Air freight for samples, urgent project deliveries or small quantities.

· Sea freight by LCL or FCL for project quantities and cost-sensitive international delivery.

· Road / rail freight where destination and trade route allow.

· Door-to-door logistics can be arranged subject to destination, Incoterm, consignee information and local import conditions.

· Express courier is generally reserved for spare parts, lamps, drivers, controls and small accessories rather than complete large light-tower cases.

8. Commercial Reference

Production lead time

Typically 15-25 working days for standard confirmed configurations; customized versions typically 20-35 working days.

Warranty

Reference commercial standard: 12 months from shipment against manufacturing defects. Final quotation / sales contract governs.

Warranty exclusions

Consumable lamps, normal wear, batteries unless separately stated, physical damage, improper power supply, operation outside approved environmental limits, unauthorized modification and misuse.

After-sales support

Remote technical support, troubleshooting guidance and replacement parts subject to confirmed order configuration and diagnostic evidence.

Spare parts

Lamps, ballast/driver, envelope, blower, cables/connectors, controls and selected mechanical parts can be quoted according to model.

Order confirmation

Final model code, voltage/frequency, tower height, light source, ballast/driver, control, CCT/CRI, cable/plug, branding, packing and destination must be confirmed before production.

9. Inquiry / RFQ Checklist

· Application and work-site description

· Required illuminated area and target lux level

· Preferred tower height or site height limitation

· Input voltage/frequency and available power source

· Need for battery / AC-DC operation and target runtime, if applicable

· CCT, CRI and flicker/camera requirements

· Control requirement: on/off, step dimming, continuous dimming, remote, DMX or APP

· Wind/weather environment and anchoring conditions

· Quantity, destination country/port, preferred transport mode and packing expectation

· Logo / branding artwork and required accessories


10. FAQ

Which tower height should I choose?

The family supports 2.0-5.0 m project heights. For SMD400SP, the normal recommendation is 3.0-4.0 m. Final height should be selected from required lux, coverage, wind exposure and transport limits.

How large an area can it illuminate?

The planning reference is up to about 5,000 m² at the very low 1-lux boundary and about 1,000 m² at 10 lux. A more practical 10-20 lux working-zone planning range is about 500-1,000 m². Higher task-light levels reduce the effective area substantially.

Can it run from batteries?

Battery operation is not the standard architecture for this model; ask for a project evaluation if required.

Is the light flicker-free?

Direct-AC boards may exhibit mains-frequency flicker. Not recommended for high-speed filming unless a verified low-flicker board architecture is specifically selected.

Can CCT and CRI be customized?

5000-6500 K standard planning range; other CCT options subject to board availability. Typically Ra >=80 for professional configurations; entry versions may use Ra 70-80 boards. Higher-CRI options are project-dependent. Final availability depends on the selected lamp/LED package.

Is it waterproof and wind resistant?

The system is designed for outdoor temporary use, but the exact IP declaration and permitted wind speed must be confirmed for the approved electrical package, tower height, base and guy-line/anchoring method. Do not treat a legacy value as universal across all 2026 models.

Can our logo be printed on the tower?

Yes. Logo, project identity and selected graphics can be applied to compatible envelope materials. Artwork and print area are confirmed before production.

What are the warranty and lead time?

Reference warranty is 12 months against manufacturing defects from shipment, subject to final quotation/sales contract and exclusions for consumables, lamps, batteries and misuse. Typically 15-25 working days for standard confirmed configurations; customized versions typically 20-35 working days.

11. Related Models

SMD1000SP, SMD2000SP, MH400SP, XN400SP.

Use related models to compare source technology, restart behavior, control capability and cost positioning before choosing a higher wattage.


Project Inquiry · Technical & Commercial

Send Your Custom Product Requirement

Tell us the product family, intended application, size, quantity, operating conditions and delivery target. Your inquiry email will automatically include the page you are viewing so our team can understand the exact product, technology or reference that led to your request.

  • Product family or model of interest
  • Required size, quantity and customization
  • Application, installation and operating environment
  • Project country, operating conditions and delivery target
Inquiry context Current page details will be attached automatically.