Columus
COLUMUS™
COLUMUS™Columus Final Model Index & Selection Guide1. Complete Model IndexModelTierLight SourcePowerReference OutputHeight10-20 lx Planning AreaMH250SPSPMetal Halide250 W20,000-25,000 lm engineering reference2.5-3.0 m225-450 m²MH400SPSPMetal Halide400 W36,000-39,000 lm legacy reference3.0-4.0
COLUMUS™
Columus Final Model Index & Selection Guide
1. Complete Model Index | ||||||
Model | Tier | Light Source | Power | Reference Output | Height | 10-20 lx Planning Area |
MH250SP | SP | Metal Halide | 250 W | 20,000-25,000 lm engineering reference | 2.5-3.0 m | 225-450 m² |
MH400SP | SP | Metal Halide | 400 W | 36,000-39,000 lm legacy reference | 3.0-4.0 m | 354-707 m² |
MH1000SP | SP | Metal Halide | 1000 W | 100,000-110,000 lm legacy reference | 4.0 m (3.0-5.0 m by project) | 982-1,963 m² |
MH2000SP | SP | Metal Halide | 2000 W | 190,000-220,000 lm engineering reference | 4.0-5.0 m | 2,050-4,100 m² |
HMI575SP | SP | HMI | 575 W | Approx. 49,000 lm legacy/engineering reference | 3.0-4.0 m | 490-980 m² |
HMI1200SP | SP | HMI | 1200 W | Approx. 110,000 lm legacy/engineering reference | 4.0 m (3.0-5.0 m by project) | 1,100-2,200 m² |
XN200SP | SP | Xenon (XN) | 200 W | Approx. 20,000 lm legacy reference | 2.5-3.0 m | 190-380 m² |
XN400SP | SP | Xenon (XN) | 400 W | Approx. 40,000 lm legacy reference | 3.0-4.0 m | 402-804 m² |
XN600SP | SP | Xenon (XN) | 600 W | Approx. 60,000 lm engineering reference | 3.0-4.0 m | 600-1,200 m² |
XN800SP | SP | Xenon (XN) | 800 W | Approx. 80,000 lm engineering reference | 3.0-4.0 m | 800-1,600 m² |
COB400SP | SP | LED - COB | 400 W | 48,000-60,000 lm design target | 3.0-4.0 m | 540-1,080 m² |
COB800SP | SP | LED - COB | 800 W | 96,000-120,000 lm design target | 3.0-4.0 m | 1,080-2,160 m² |
COB1200SP | SP | LED - COB | 1200 W | 144,000-180,000 lm design target | 4.0 m (3.0-5.0 m by project) | 1,620-3,240 m² |
SMD400SP | SP | LED - AC SMD | 400 W | 44,000-56,000 lm design target | 3.0-4.0 m | 500-1,000 m² |
SMD1000SP | SP | LED - AC SMD | 1000 W | 110,000-140,000 lm design target | 4.0 m (3.0-5.0 m by project) | 1,250-2,500 m² |
SMD2000SP | SP | LED - AC SMD | 2000 W | 220,000-280,000 lm design target | 4.0-5.0 m | 2,500-5,000 m² |
MH240SE | SE | Metal Halide | 240 W | 18,000-24,000 lm engineering reference | 2.5-3.0 m | 210-420 m² |
MH400SE | SE | Metal Halide | 400 W | 36,000-39,000 lm legacy reference | 3.0-4.0 m | 354-707 m² |
MH1000SE | SE | Metal Halide | 1000 W | 100,000-110,000 lm legacy reference | 4.0 m (3.0-5.0 m by project) | 982-1,963 m² |
HMI575SE | SE | HMI | 575 W | Approx. 49,000 lm legacy/engineering reference | 3.0-4.0 m | 490-980 m² |
XN400SE | SE | Xenon (XN) | 400 W | Approx. 40,000 lm legacy reference | 3.0-4.0 m | 402-804 m² |
XN800SE | SE | Xenon (XN) | 800 W | Approx. 80,000 lm engineering reference | 3.0-4.0 m | 800-1,600 m² |
COB400SE | SE | LED - COB | 400 W | 48,000-60,000 lm design target | 3.0-4.0 m | 540-1,080 m² |
SMD400SE | SE | LED - AC SMD | 400 W | 44,000-56,000 lm design target | 3.0-4.0 m | 500-1,000 m² |
SMD1000SE | SE | LED - AC SMD | 1000 W | 110,000-140,000 lm design target | 4.0 m (3.0-5.0 m by project) | 1,250-2,500 m² |
MH400EN | EN | Metal Halide | 400 W | 36,000-39,000 lm legacy reference | 3.0-4.0 m | 354-707 m² |
XN200EN | EN | Xenon (XN) | 200 W | Approx. 20,000 lm legacy reference | 2.5-3.0 m | 190-380 m² |
XN400EN | EN | Xenon (XN) | 400 W | Approx. 40,000 lm legacy reference | 3.0-4.0 m | 402-804 m² |
SMD400EN | EN | LED - AC SMD | 400 W | 44,000-56,000 lm design target | 3.0-4.0 m | 500-1,000 m² |
SMD800EN | EN | LED - AC SMD | 800 W | 88,000-112,000 lm design target | 3.0-4.0 m | 1,000-2,000 m² |
HMI575AP | AP | HMI | 575 W | Approx. 49,000 lm planning reference | 3.0-4.0 m | 490-980 m² |
HMI1200AP | AP | HMI | 1200 W | Approx. 110,000 lm planning reference | 4.0 m (3.0-5.0 m by project) | 1,100-2,200 m² |
LED400AP | AP | Low-Noise LED | 400 W | 45,000-60,000 lm design target | 3.0-4.0 m | 525-1,050 m² |
LED800AP | AP | Low-Noise LED | 800 W | 90,000-120,000 lm design target | 3.0-4.0 m | 1,050-2,100 m² |
2. Quick Selection Logic | ||||||
· Need lowest complexity / entry price: start with EN.
· Need standardized professional value: start with SE.
· Need widest light-source, material and control options: start with SP.
· Need low-noise sealed-air architecture: evaluate AP as a custom project.
· Need immediate/near-immediate restart: prioritize XN or LED.
· Need professional daylight and film/event support: prioritize HMI or specified low-flicker/high-CRI COB/AP LED.
· Need advanced dimming/DMX/APP: prioritize COB or AP LED.
· Need simplified cost-efficient LED: prioritize AC SMD.
· Need battery operation: prioritize XN200/XN400 or COB400; confirm runtime from actual electrical input and battery capacity.
3. Public-Data Validation Rules |
· Keep legacy validated/reference values clearly identified.
· Do not publish engineering planning lumens, coverage, wind or IP as guaranteed values until testing is complete.
· Do not use 1-lux coverage as a practical work-area claim without context.
· Packing dimensions and weights are always reconfirmed before shipment.
· Warranty and production lead time are reference commercial standards; signed quotation/sales contract governs.
Send Your Custom Product Requirement
Tell us the product family, intended application, size, quantity, operating conditions and delivery target. Your inquiry email will automatically include the page you are viewing so our team can understand the exact product, technology or reference that led to your request.
- Product family or model of interest
- Required size, quantity and customization
- Application, installation and operating environment
- Project country, operating conditions and delivery target