Professional Inflatable Tents
Large Inflatable Hangars & Industrial Shelters | Custom Inflatable Manufacturer | BTCOOPS
Large Inflatable Hangars & Industrial Shelters for professional event, commercial and project applications. Standard size platforms, custom design, material and configuration options from BTCOOPS / Wuxi FENIGAL.
Large Inflatable Hangars & Industrial Shelters
Rapid-deploy large-span pneumatic buildings for aviation MRO, vehicles, industrial maintenance, warehousing and remote operations. |
Category Overview & Commercial Positioning
Large inflatable hangars are engineered building systems. The website should offer scalable span/length platforms and clearly separate “reference configuration” from final structural design. Door geometry, weather loads, anchoring, inflation control, backup power and fire approval are as important as the nominal envelope dimensions.
Product / Model Matrix
Website Model | Product / Configuration | Standard Size or Range | Inflation / Structure | Primary Material | Typical Market Application |
HGR-8124 | Compact Vehicle / UAV Shelter | 8 x 12 x 4 m class | Regulated pneumatic frame | PVDF/PVC coated structural textile | UAV, vehicle service, field workshop |
HGR-1320 | Medium Maintenance Shelter | 13 m span x 20 m L | Pneumatic / air-beam project system | Structural coated textile | Vehicles, helicopters, field maintenance |
HGR-1620 | Large Maintenance Shelter | 16 m span x 20 m L | Pneumatic frame | Structural PVC/PVDF textile | Helicopter/vehicle MRO |
HGR-2020 | Aircraft Maintenance Shelter | 20 m span x 20 m L | Pneumatic frame | Structural coated textile | Aircraft/UAV maintenance |
HGR-2030 | Aircraft Hangar 20x30 | 20 x 30 m class | Regulated air-beam / pneumatic frame | Heavy PVC/PVDF coated textile | Helicopter/fixed-wing temporary hangar |
HGR-2430 | Wide-Span Hangar | 24 m span x 30 m L class | Engineered pneumatic frame | PVDF/PVC structural membrane | Aviation MRO / industrial |
HGR-503015 | Large Aircraft Hangar | 50 x 30 x 15 m reference | Low-pressure air-beam project system | Airtight PVC frame + weather cover | Aircraft storage/MRO |
HGR-6010024 | Mega Pneumatic Hangar | 60 x 100 x 24 m outer reference | Regulated low-pressure air ribs | 1300 g/m²-class PVDF ribs + ~950 g/m² cover reference | Major aviation/industrial project |
Model Data Cards for Product Detail Pages
HGR-8124 | Compact Vehicle / UAV Shelter
Recommended standard configuration: 8 x 12 x 4 m class. Regulated pneumatic frame; PVDF/PVC coated structural textile. Intended for uav, vehicle service, field workshop.
Options: Roll-up/end door, lights, HVAC
HGR-1320 | Medium Maintenance Shelter
Recommended standard configuration: 13 m span x 20 m L. Pneumatic / air-beam project system; Structural coated textile. Intended for vehicles, helicopters, field maintenance.
Options: Extendable 5 m modules Engineering note: 13x20 m class aligns with established rapid-deployment shelter market.
HGR-1620 | Large Maintenance Shelter
Recommended standard configuration: 16 m span x 20 m L. Pneumatic frame; Structural PVC/PVDF textile. Intended for helicopter/vehicle mro.
Options: Modular length, doors
HGR-2020 | Aircraft Maintenance Shelter
Recommended standard configuration: 20 m span x 20 m L. Pneumatic frame; Structural coated textile. Intended for aircraft/uav maintenance.
Options: HVAC, lighting, flooring
HGR-2030 | Aircraft Hangar 20x30
Recommended standard configuration: 20 x 30 m class. Regulated air-beam / pneumatic frame; Heavy PVC/PVDF coated textile. Intended for helicopter/fixed-wing temporary hangar.
Options: Large door, control cabinet, standby blower
HGR-2430 | Wide-Span Hangar
Recommended standard configuration: 24 m span x 30 m L class. Engineered pneumatic frame; PVDF/PVC structural membrane. Intended for aviation mro / industrial.
Options: Modular extension, electric door
HGR-503015 | Large Aircraft Hangar
Recommended standard configuration: 50 x 30 x 15 m reference. Low-pressure air-beam project system; Airtight PVC frame + weather cover. Intended for aircraft storage/mro.
Options: Control, lighting, HVAC Engineering note: Current China market offers this envelope; structural loads must be engineered.
HGR-6010024 | Mega Pneumatic Hangar
Recommended standard configuration: 60 x 100 x 24 m outer reference. Regulated low-pressure air ribs; 1300 g/m²-class PVDF ribs + ~950 g/m² cover reference. Intended for major aviation/industrial project.
Options: Automatic pressure control, doors, backup blowers Engineering note: Use only as project reference; manufacturer-specific values are not universal.
Shared Technical Architecture
· Rapid-deploy shelters use sealed low-pressure or high-pressure air-beam frames, or continuously regulated pneumatic frames for very large spans. The frame fabric, outer cover, floor and insulation are selected separately for function.
· Typical construction combines reinforced airtight PVC/TPU air beams, coated Oxford/PVC or PVDF weather cover, PVC groundsheet, replaceable doors/windows and external guying/anchoring.
· Project options include vestibules, interconnection tunnels, partitions, HVAC interfaces, filtration, lighting, electrical distribution, pressure monitoring, automatic inflation control, flooring and packaging/transport frames.
· Wind, snow, rain, temperature, foundation/anchor capacity, door opening loads and emergency egress are structural inputs. Large shelters and hangars require project engineering and cannot be published with a universal weather rating.
· For medical/decontamination use, zoning, washable inner surfaces, drainage, HVAC pressure control, filtration and cleaning/disinfection compatibility must be defined at project stage.
Selection & Quotation Inputs
· Provide clear internal footprint and clear height, equipment/vehicle envelope, door dimensions and required unobstructed working zones.
· State deployment manpower/time target, transport constraint, power availability and whether standby inflation or generator backup is required.
· Provide design wind, snow, rainfall, temperature range and ground/anchoring conditions for the actual site.
· For medical/fire/decontamination shelters provide patient/process flow, clean/dirty zoning, HVAC/filtration, drainage and utility interfaces.
· For aviation/industrial hangars provide aircraft/vehicle CAD envelope, door operation, maintenance clearances, lighting/HVAC loads and local building/fire approval requirements.
Send Your Custom Product Requirement
Tell us the product family, intended application, size, quantity, operating conditions and delivery target. Your inquiry email will automatically include the page you are viewing so our team can understand the exact product, technology or reference that led to your request.
- Product family or model of interest
- Required size, quantity and customization
- Application, installation and operating environment
- Project country, operating conditions and delivery target