1. Product Introduction & Positioning |
Columus MH2000SP is a 2000 W metal-halide inflatable light tower designed for broad 360-degree temporary area lighting. It combines a portable inflatable column with a mature HID light engine and is aimed at industrial, construction, infrastructure and emergency work where strong output and proven lamp technology are more important than instant hot restart.
Series positioning: SP - Standard Pro (Professional / upper-standard). The tower uses premium translucent flame-retardant, uv-resistant composite envelope and is intended for industrial night work, emergency response, rescue, infrastructure, mining, ports, airports, professional event support and film/TV support zones. This model should be selected from required illuminance, work-zone size, tower height, power source, restart behavior, color/flicker needs and environmental conditions rather than lamp wattage alone.
2. At a Glance | |||
Item | Data | Item | Data |
Model | MH2000SP | Series | SP - Standard Pro |
Light source | Metal Halide | Rated light power | 2000 W |
Reference output | 190,000-220,000 lm engineering reference | Recommended height | 4.0-5.0 m |
Max. reference area (>=1 lx) | Approx. 20,500 m² | Reference area at 10 lx | Approx. 4,100 m² |
Practical 10-20 lx area | Approx. 2,050-4,100 m² | Reference center illuminance at 4 m | Approx. 3,895 lx |
Photometric values: MH400/MH1000/XN200/XN400 anchor values trace to legacy Columus data. Other outputs/areas are engineering planning references derived for product selection and must be replaced by final measured photometric data before being stated as guaranteed performance.
3. Detailed Technical Specifications | |
Light-source platform | HID metal-halide lamp |
Rated light power | 2000 W |
Reference system output | 190,000-220,000 lm engineering reference |
Color temperature | ~4200 K typical |
Color rendering | Typically Ra 65-80, lamp-dependent; higher-CRI lamp packages can be evaluated |
Flicker behavior | Magnetic ballast versions may show mains-frequency flicker. Electronic-ballast versions can provide steadier / lower-flicker output; camera use requires project confirmation. |
Start / restrike | Warm-up required; legacy hot-restrike reference approximately 8-10 minutes |
Light-source service life | Lamp life is lamp/ballast dependent; legacy standard references up to approximately 10,000 h under normal conditions |
Power supply | AC mains / generator, typically 120 V or 220-240 V AC, 50/60 Hz subject to approved ballast |
Control | On/Off standard; electronic-ballast versions may support enhanced switching or project-specific control |
Tower architecture | Continuous-air inflatable tower with integrated low-power blower |
Envelope material | Premium translucent flame-retardant, UV-resistant composite envelope |
Tower-height options | 2.0 / 2.5 / 3.0 / 4.0 / 5.0 m project options; not every height is recommended for every light head |
Recommended height | 4.0-5.0 m |
Typical tower body | Approx. 400 mm class tower body; final head/base dimensions depend on configuration |
Inflation / blower | Continuous-running blower typically 80-150 W depending on tower height and light-head mass |
Typical deployment | Typically 2-5 minutes by one trained operator, depending on packing, anchoring and guy-line arrangement |
Outdoor / wind / IP | Outdoor weather-resistant construction. Exact declared IP rating and wind limit must be confirmed for the approved model, electrical package and anchoring method. |
4. Lighting Performance & Application Boundary |
For project planning, MH2000SP is estimated to provide a maximum low-level illumination footprint of approximately 20,500 m² at the 1-lux boundary and approximately 4,100 m² at 10 lux. For general orientation, emergency staging and broad work-zone lighting, a more practical 10-20 lux planning range is approximately 2,050-4,100 m². Applications requiring 50-100 lux or more will cover a much smaller area and should be checked with a project-specific lux layout.
Application boundary: Not preferred where immediate hot restart, very frequent switching or camera-oriented flicker performance is the primary requirement.
Recommended Applications
· Construction and roadwork
· Industrial maintenance and shutdown work
· Mining, ports, airports and rail operations
· Fire/rescue staging where immediate hot restart is not essential
Representative Application Cases
Case 1. Large industrial yard or open work zone requiring high-output temporary area illumination.
Case 2. Major infrastructure or mining project where one portable tower must cover a broad operating zone.
Case 3. Remote generator-powered night work where maximum output is prioritized over instant hot restart.
Cases above are representative application scenarios for positioning and selection. They are not claims of a named customer installation unless supported by a separately approved project reference.
5. Customer Value & Selection Guidance |
· Mature high-output HID platform
· Strong cost/output ratio at medium and high power
· Simple industrial operating logic
· Broad 360° diffused illumination
Choose MH2000SP when its metal halide behavior, 2000 W output class and SP series positioning match the project priorities. If the customer needs different restart behavior, control sophistication, budget level or tower material, compare related Columus models rather than increasing wattage alone.
6. Customization & OEM/ODM Options |
· Tower height: 2.0 / 2.5 / 3.0 / 4.0 / 5.0 m project options; 3.0 m and 4.0 m are the most common family configurations.
· Envelope color, logo printing and project identification graphics, subject to material and print-process suitability.
· Input voltage, plug type, cable length, connector arrangement and generator interface for the target market.
· Light-source package: ~4200 K typical; color rendering options follow the selected lamp/LED package.
· Protective transport packaging: reinforced export carton, plywood case or reusable flight case depending on project and shipping mode.
· Guy ropes, pegs, sandbags/ballast points, spare envelope, spare electrical parts and extension cables can be supplied as project accessories.
· Magnetic ballast as the conventional standard; electronic ballast can be specified for steadier / lower-flicker operation.
Customization is subject to engineering review, component availability, certification scope and final quotation. Drawings, control architecture, logo artwork and special packing may require approval before production.
7. Product Size, Packing & Shipping | |
Non-working / collapsed product size | 55 x 45 x 45 cm |
Working size | Approx. 40 x 40 x selected tower height; reference 4 m working size approx. 40 x 40 x 400 cm |
Reference export packing size | 66 x 56 x 56 cm |
Reference net weight | 47-55 kg |
Reference packed weight | 62-72 kg |
Standard protective packing | Protective internal foam/wrapping plus reinforced export packing. Professional orders may use plywood or reusable flight case. |
Optional split packing | Large ballast/driver or high-power light head may be packed as a separate electrical case to improve handling and protect components. |
Packing dimensions and weight are logistics planning references only. Final packing size, number of packages, net/gross weight and case type must be reconfirmed before shipment because tower height, ballast/driver, lamp head, cable length, battery option and accessories can change the final package.
Shipping Options
· Air freight for samples, urgent project deliveries or small quantities.
· Sea freight by LCL or FCL for project quantities and cost-sensitive international delivery.
· Road / rail freight where destination and trade route allow.
· Door-to-door logistics can be arranged subject to destination, Incoterm, consignee information and local import conditions.
· Express courier is generally reserved for spare parts, lamps, drivers, controls and small accessories rather than complete large light-tower cases.
8. Commercial Reference | |
Production lead time | Typically 15-25 working days for standard confirmed configurations; customized versions typically 20-35 working days. |
Warranty | Reference commercial standard: 12 months from shipment against manufacturing defects. Final quotation / sales contract governs. |
Warranty exclusions | Consumable lamps, normal wear, batteries unless separately stated, physical damage, improper power supply, operation outside approved environmental limits, unauthorized modification and misuse. |
After-sales support | Remote technical support, troubleshooting guidance and replacement parts subject to confirmed order configuration and diagnostic evidence. |
Spare parts | Lamps, ballast/driver, envelope, blower, cables/connectors, controls and selected mechanical parts can be quoted according to model. |
Order confirmation | Final model code, voltage/frequency, tower height, light source, ballast/driver, control, CCT/CRI, cable/plug, branding, packing and destination must be confirmed before production. |
9. Inquiry / RFQ Checklist | |
· Application and work-site description
· Required illuminated area and target lux level
· Preferred tower height or site height limitation
· Input voltage/frequency and available power source
· Need for battery / AC-DC operation and target runtime, if applicable
· CCT, CRI and flicker/camera requirements
· Control requirement: on/off, step dimming, continuous dimming, remote, DMX or APP
· Wind/weather environment and anchoring conditions
· Quantity, destination country/port, preferred transport mode and packing expectation
· Logo / branding artwork and required accessories
10. FAQ |
Which tower height should I choose?
The family supports 2.0-5.0 m project heights. For MH2000SP, the normal recommendation is 4.0-5.0 m. Final height should be selected from required lux, coverage, wind exposure and transport limits.
How large an area can it illuminate?
The planning reference is up to about 20,500 m² at the very low 1-lux boundary and about 4,100 m² at 10 lux. A more practical 10-20 lux working-zone planning range is about 2,050-4,100 m². Higher task-light levels reduce the effective area substantially.
Can it run from batteries?
Not as the standard recommendation. AC mains or generator power is normally preferred at this power level.
Is the light flicker-free?
Magnetic ballast versions may show mains-frequency flicker. Electronic-ballast versions can provide steadier / lower-flicker output; camera use requires project confirmation.
Can CCT and CRI be customized?
~4200 K typical. Typically Ra 65-80, lamp-dependent; higher-CRI lamp packages can be evaluated Final availability depends on the selected lamp/LED package.
Is it waterproof and wind resistant?
The system is designed for outdoor temporary use, but the exact IP declaration and permitted wind speed must be confirmed for the approved electrical package, tower height, base and guy-line/anchoring method. Do not treat a legacy value as universal across all 2026 models.
Can our logo be printed on the tower?
Yes. Logo, project identity and selected graphics can be applied to compatible envelope materials. Artwork and print area are confirmed before production.
What are the warranty and lead time?
Reference warranty is 12 months against manufacturing defects from shipment, subject to final quotation/sales contract and exclusions for consumables, lamps, batteries and misuse. Typically 15-25 working days for standard confirmed configurations; customized versions typically 20-35 working days.
11. Related Models |
MH250SP, MH400SP, MH1000SP, SMD2000SP.
Use related models to compare source technology, restart behavior, control capability and cost positioning before choosing a higher wattage.
Send Your Custom Product Requirement
Tell us the product family, intended application, size, quantity, operating conditions and delivery target. Your inquiry email will automatically include the page you are viewing so our team can understand the exact product, technology or reference that led to your request.
- Product family or model of interest
- Required size, quantity and customization
- Application, installation and operating environment
- Project country, operating conditions and delivery target