Fenigal Btcoops - Specialized Balloon Light, Inflatables, Electricals, Equipment and Tools
Fenigal Btcoops - Specialized Balloon Light, Inflatables, Electricals, Equipment and Tools
Translate this website

Google Translate is loaded only when you open this panel, reducing unnecessary requests and layout work during the first page load.

Loading language options…
Request Quote

Columus

Professional Product Detail

Columus EN Entry Normal Inflatable Light Towers

Columus EN Entry Normal inflatable light towers for general temporary lighting, budget-sensitive rental, local maintenance, portable emergency staging and ou...

Category: Columus

COLUMUS™

Columus EN - Entry Normal Series Overview

Product Positioning, Model Range, Applications, Technical Architecture & Commercial Guidance

Final English series guide

1. Series Positioning

Columus EN - Entry Normal is the entry / essential-function branch of the Columus inflatable light-tower family. It uses oxford fabric or equivalent commercial entry-grade envelope and continuous-air inflatable tower with integrated low-power blower. The series is aimed at general temporary lighting, budget-sensitive rental, local maintenance, portable emergency staging and outdoor utility work.

EN focuses on essential lighting value and simple operation. It deliberately limits source and power combinations to reduce complexity and cost while retaining the core benefit of a portable elevated diffused light tower.

2. Application Difference & Relationship to Other Columus Series


Series

Full Name

Position

Material / Structure

Typical Use

SP

Standard Pro

Professional / upper-standard

Premium translucent flame-retardant, UV-resistant composite envelope

industrial night work, emergency response, rescue, infrastructure, mining, ports, airports, professional event support and film/TV support zones

SE

Standard Economic

Professional value / standardized

Flame-retardant waterproof rip-stop nylon envelope

construction, road works, fire and rescue, municipal maintenance, rental fleets, rail maintenance and general outdoor operations

EN

Entry Normal

Entry / essential-function

Oxford fabric or equivalent commercial entry-grade envelope

general temporary lighting, budget-sensitive rental, local maintenance, portable emergency staging and outdoor utility work

AP

Advance Pro

Premium / low-noise custom-engineered

Multi-layer sealed inner air cell plus protective/diffusing outer envelope; material stack is project-engineered

film and broadcast support, premium event perimeters, acoustically sensitive locations, exhibitions, ceremonies and specialist custom projects

The EN series shares the core Columus concept - an elevated diffused light source for fast temporary area illumination - but differs from the other branches in material, light-source choice, electrical/control sophistication, acoustic behavior and commercial positioning.

3. Model Range

Model

Source

Power

Reference Output

Recommended Height

10-20 lx Area

MH400EN

Metal Halide

400 W

36,000-39,000 lm legacy reference

3.0-4.0 m

354-707 m²

XN200EN

Xenon (XN)

200 W

Approx. 20,000 lm legacy reference

2.5-3.0 m

190-380 m²

XN400EN

Xenon (XN)

400 W

Approx. 40,000 lm legacy reference

3.0-4.0 m

402-804 m²

SMD400EN

LED - AC SMD

400 W

44,000-56,000 lm design target

3.0-4.0 m

500-1,000 m²

SMD800EN

LED - AC SMD

800 W

88,000-112,000 lm design target

3.0-4.0 m

1,000-2,000 m²

4. Technical Architecture

Series architecture

Continuous-air inflatable tower with integrated low-power blower

Envelope / structural material

Oxford fabric or equivalent commercial entry-grade envelope

Tower heights

2.0 / 2.5 / 3.0 / 4.0 / 5.0 m project options; 3.0 and 4.0 m are the most common family heights

Tower body

Approx. 400 mm class; final light head/base dimensions depend on configuration

Wind / weather

Model-specific confirmation required. Exact IP and wind limit follow final approved construction and anchoring.

Power

AC mains / generator across the range; selected low-power XN or COB versions can support DC or AC/DC operation

Branding

Logo / project identification on compatible tower envelopes

Packing

Reinforced export packing, plywood case or reusable flight case; final dimensions/weight reconfirmed before shipment

5. Light-Source Strategy

Technology

Platform

Start/Restrike

Control

Best-use Boundary

Metal Halide

HID metal-halide lamp

Warm-up required; legacy hot-restrike reference approximately 8-10 minutes

On/Off standard; electronic-ballast versions may support enhanced switching or project-specific control

Not preferred where immediate hot restart, very frequent switching or camera-oriented flicker performance is the primary requirement.

Xenon (XN)

Automotive-type xenon / HID lamp modules

Instant / near-instant restrike; well suited to frequent switching

On/Off; multi-circuit switching can be engineered where the lamp arrangement allows

Battery operation is most practical at about 400 W and below. Higher-power XN is normally better on AC/generator because battery size and runtime become less attractive.

LED - AC SMD

Direct-AC SMD LED board

Instant

On/Off standard; optional two-step power switching where configured

Best where simplified construction and lower cost are more important than advanced dimming, DMX or camera-grade flicker performance.

6. Applications & Representative Cases

· Road or utility repair zone: portable 360-degree work-area illumination for short-term night maintenance.

· Fire / rescue staging area: broad scene lighting from mains or a portable generator where instant hot restart is not essential.

· Rail or construction maintenance: quickly deployed temporary tower lighting without a heavy telescopic mast.

· Police checkpoint or temporary traffic-control lane requiring frequent switching and fast restart.

· Portable rescue / inspection operation using a battery package where generator-free mobility is valuable.

· Field camp, forensic or rapid-response work zone requiring compact setup and immediate light output.

· Construction and road work where simple AC operation and low component count are priorities.

· Rental fleet or local contractor use requiring fast deployment and straightforward on/off operation.

Representative cases are positioning scenarios, not named customer references unless separately approved.

7. Selection Guidance

· Select EN when simple operation, lower system cost and essential functions are more important than advanced control.

· MH400EN is the mature HID baseline.

· XN200EN/XN400EN fit portable rapid-response work and battery-capable low-power requirements.

· SMD400EN/SMD800EN provide the simplified LED route.

8. Commercial Reference

Lead time

Typically 10-18 working days for standard confirmed configurations; customized versions typically 20-35 working days.

Reference warranty

12 months from shipment against manufacturing defects; final quotation/sales contract governs.

Customization

Tower height, voltage, plug/cable, CCT/CRI, ballast/driver, control, branding, accessories and packing subject to engineering review.

Shipping

Air freight, sea LCL/FCL, road/rail where suitable, and project-specific door-to-door logistics.

Packing note

All dimensions and weights are planning references until the final ordered configuration and shipment packing are confirmed.

 


Project Inquiry · Technical & Commercial

Send Your Custom Product Requirement

Tell us the product family, intended application, size, quantity, operating conditions and delivery target. Your inquiry email will automatically include the page you are viewing so our team can understand the exact product, technology or reference that led to your request.

  • Product family or model of interest
  • Required size, quantity and customization
  • Application, installation and operating environment
  • Project country, operating conditions and delivery target
Inquiry context Current page details will be attached automatically.