Fenigal Btcoops - Specialized Balloon Light, Inflatables, Electricals, Equipment and Tools
Fenigal Btcoops - Specialized Balloon Light, Inflatables, Electricals, Equipment and Tools
Translate this website

Google Translate is loaded only when you open this panel, reducing unnecessary requests and layout work during the first page load.

Loading language options…
Request Quote

Inflatable Fans and Blowers

Professional Product Detail

Compact Fans for Small Displays, Props and Inflatable Costumes | Inflatable Air System Solutions

Balance fan weight, battery energy, guarded airflow and service access for small or wearable products. Typical performance, installation, customer value, application cases and OEM options are included.

Category: Inflatable Fans and Blowers

F&B-41

SERIES 4 - COMPACT VORTEX AND AXIAL FANS

Compact Fans for Small Displays, Props and Inflatable Costumes

Lightweight airflow where size, sound and mobility matter as much as pressure.

Compact Fans for Small Displays, Props and Inflatable Costumes focuses on embedded inflation, small displays, illuminated props, costumes, electronics bays, ventilation and cooling. It uses miniature radial / vortex modules for pressure and axial fans for low-resistance ventilation to match the airflow behavior to the product rather than forcing one generic fan across unrelated inflatable forms. Balance fan weight, battery energy, guarded airflow and service access for small or wearable products.

The core website envelope is approximately 20-400 W across AC and low-voltage DC platforms, 40-400 m³/h for the core embedded range; selected axial modules can deliver more at low resistance and 0.3-1.5 kPa for standard embedded products; specialized radial modules may reach more at lower flow. These numbers are presented as a selection range, not as a guaranteed model. The final duty point must be confirmed after voltage, frequency, altitude, ambient temperature, duct geometry, fabric leakage and operating hours are known.

Product and Engineering Snapshot

Selection item

Typical specification / content

Product positioning

embedded inflation, small displays, illuminated props, costumes, electronics bays, ventilation and cooling

Air technology

miniature radial / vortex modules for pressure and axial fans for low-resistance ventilation

Typical power

20-400 W across AC and low-voltage DC platforms

Typical airflow

40-400 m³/h for the core embedded range; selected axial modules can deliver more at low resistance

Typical static pressure

0.3-1.5 kPa for standard embedded products; specialized radial modules may reach more at lower flow

Installation forms

internal flange, bracket, panel, duct insert, electronics bay or removable cartridge

Special functions

brushless DC, PWM / voltage control, low-noise bearings, temperature feedback, custom harness and quick connector

Parameter note: all values are representative engineering envelopes, not a promise for every model. Final selection must be confirmed against the performance curve at the actual voltage, frequency, altitude, ambient temperature, duct length, outlet geometry and required operating pressure.

Product Positioning and Customer Value

Balance fan weight, battery energy, guarded airflow and service access for small or wearable products. The solution should solve a visible operating problem: soft or unstable fabric, slow recovery, excessive noise, awkward installation, repeated overheating, too many incompatible spare parts, or long deployment time.

Value 1. Fits into bases, props and products where a floor blower would spoil the appearance.

Value 2. Separates pressure-oriented inflation from high-flow ventilation and cooling.

Value 3. Supports 12, 24 and 48 V mobile or integrated product architectures.

Application-specific integration. Balance fan weight, battery energy, guarded airflow and service access for small or wearable products. This creates a clearer path from the inflatable requirement to a serviceable product package.

Where This Page Creates Value

Representative use patterns include Mascot costume, Tabletop display, Stage prop, Character detail and Museum display. Each application changes the balance between airflow, static pressure, noise, installation space and service access. For this reason, the application list should be used as a routing guide: the final blower recommendation follows the actual inlet, duct and prototype pressure behavior.

· Mascot costume: low-voltage axial or radial module. The selection should be confirmed against the complete installed resistance and duty.

· Tabletop display: quiet embedded fan. The selection should be confirmed against the complete installed resistance and duty.

· Stage prop: battery or hidden cable. The selection should be confirmed against the complete installed resistance and duty.

· Character detail: radial fan into narrow passages. The selection should be confirmed against the complete installed resistance and duty.

· Museum display: long-duty low-noise module. The selection should be confirmed against the complete installed resistance and duty.

Representative Application Case

A costume must stay shaped for a 45-minute appearance while the performer walks and waves.

A costume must stay shaped for a 45-minute appearance while the performer walks and waves. The case is intentionally representative rather than tied to an original equipment source. It shows how the product page can translate a customer scenario into a practical engineering recommendation.

Challenge: The fan must remain light, guarded and reliable despite body movement.

Configuration item

Representative application parameter

Fan

brushless DC axial or radial after leakage test

Battery

24 V, at least 60 minutes including reserve

Air path

guarded back intake and diffuser

Service

spare fan and pack with quick connectors

Customer value: The performer gets predictable run time and rapid module replacement.

The case parameters are a starting envelope. During prototype validation, check the shape at the highest and most remote zones, measure internal pressure where possible, record motor current after warm-up and confirm that the intake, discharge and electrical connections remain accessible.

Engineering and Selection Notes

· Treat the inflatable, connecting duct and blower as one air system. A high free-air number alone does not guarantee adequate pressure after bends, filters, valves, long hoses or restrictive inlets.

· Check 50 Hz and 60 Hz performance separately. Motor speed, airflow, static pressure, current and temperature rise can change with frequency and supply voltage.

· Allow an altitude and hot-weather margin. Lower air density reduces mass flow and cooling capacity, so elevated or hot installations may require derating or a larger blower.

· For outdoor use, distinguish weather-resistant construction from fully waterproof construction. Keep connections above standing water, use locally suitable ground-fault protection and inspect cords before deployment.

· Confirm the continuous-duty rating, thermal protection and allowable outlet temperature whenever the blower will run for long periods.

· Wearable applications also require user ventilation, heat, visibility, hearing, battery protection and rapid exit considerations.

Available Customization

20-400 W • 12 / 24 / 48 V DC or AC • radial / vortex / axial • PWM control • custom harness • flange and bracket • temperature sensor • removable cartridge

For OEM programs, available work can include outlet matching, housing or base layout, cable and plug selection, switch and speed-control design, labeling, packaging, service parts, sample approval and production test planning. Compliance documents must be tied to the exact final configuration.

NEXT STEP  Send the inflatable dimensions, material, inlet size, duct route, voltage/frequency, operating hours, environment and target behavior. We will recommend a pressure-flow envelope and installation architecture before confirming the final model.

Design responsibility note: blower sizing must be validated as part of the complete inflatable system. For occupied, ride-on, rescue, tent or other safety-critical inflatables, the finished product must also follow the applicable local product, electrical, anchoring, fire and operational requirements.


Project Inquiry · Technical & Commercial

Send Your Custom Product Requirement

Tell us the product family, intended application, size, quantity, operating conditions and delivery target. Your inquiry email will automatically include the page you are viewing so our team can understand the exact product, technology or reference that led to your request.

  • Product family or model of interest
  • Required size, quantity and customization
  • Application, installation and operating environment
  • Project country, operating conditions and delivery target
Inquiry context Current page details will be attached automatically.