Inflatable Fans and Blowers
Remote Medium-Pressure Blower Systems | Inflatable Air System Solutions
Move noise and heat away from guests using large ducts, proper room ventilation and pressure verification. Typical performance, installation, customer value, application cases and OEM options are included.
F&B-33 | SERIES 3 - MEDIUM-PRESSURE BLOWERS |
Remote Medium-Pressure Blower Systems
Place equipment where operations need it, then engineer pressure loss back into the system.
Remote Medium-Pressure Blower Systems focuses on large leisure inflatables, long tunnels, giant arches, tall structures, remote ducts and multi-branch installations. It uses medium-pressure centrifugal blower with reinforced housing and a motor selected for sustained pressure to match the airflow behavior to the product rather than forcing one generic fan across unrelated inflatable forms. Move noise and heat away from guests using large ducts, proper room ventilation and pressure verification.
The core website envelope is approximately 0.75-3.0 kW for the main website range, 800-3,000 m³/h at the installed operating point and 2.4-5.0 kPa. These numbers are presented as a selection range, not as a guaranteed model. The final duty point must be confirmed after voltage, frequency, altitude, ambient temperature, duct geometry, fabric leakage and operating hours are known.
Product and Engineering Snapshot
Selection item | Typical specification / content |
Product positioning | large leisure inflatables, long tunnels, giant arches, tall structures, remote ducts and multi-branch installations |
Air technology | medium-pressure centrifugal blower with reinforced housing and a motor selected for sustained pressure |
Typical power | 0.75-3.0 kW for the main website range |
Typical airflow | 800-3,000 m³/h at the installed operating point |
Typical static pressure | 2.4-5.0 kPa |
Installation forms | portable floor unit, remote ducted, skid-mounted, equipment bay or duty/standby manifold |
Special functions | multi-speed or VFD, overload and thermal protection, rugged frame, acoustic treatment, pressure feedback and weather packages |
Parameter note: all values are representative engineering envelopes, not a promise for every model. Final selection must be confirmed against the performance curve at the actual voltage, frequency, altitude, ambient temperature, duct length, outlet geometry and required operating pressure.
Product Positioning and Customer Value
Move noise and heat away from guests using large ducts, proper room ventilation and pressure verification. The solution should solve a visible operating problem: soft or unstable fabric, slow recovery, excessive noise, awkward installation, repeated overheating, too many incompatible spare parts, or long deployment time.
Value 1. Maintains meaningful airflow at several kilopascals of system resistance.
Value 2. Supports longer ducts that move noise and equipment away from users.
Value 3. Allows pressure-based commissioning, VFD control and redundancy.
Application-specific integration. Move noise and heat away from guests using large ducts, proper room ventilation and pressure verification. This creates a clearer path from the inflatable requirement to a serviceable product package.
Where This Page Creates Value
Representative use patterns include Behind-barrier arch, Stage scenic, Shelter bay, Central plant and Construction. Each application changes the balance between airflow, static pressure, noise, installation space and service access. For this reason, the application list should be used as a routing guide: the final blower recommendation follows the actual inlet, duct and prototype pressure behavior.
· Behind-barrier arch: 5-15 m duct. The selection should be confirmed against the complete installed resistance and duty.
· Stage scenic: blower backstage or below stage. The selection should be confirmed against the complete installed resistance and duty.
· Shelter bay: external skid and controls. The selection should be confirmed against the complete installed resistance and duty.
· Central plant: review branch failure risks. The selection should be confirmed against the complete installed resistance and duty.
· Construction: equipment outside access zone. The selection should be confirmed against the complete installed resistance and duty.
Representative Application Case
A scenic element uses a blower room 15 m away through three bends.
A scenic element uses a blower room 15 m away through three bends. The case is intentionally representative rather than tied to an original equipment source. It shows how the product page can translate a customer scenario into a practical engineering recommendation.
Challenge: A small duct would consume pressure and create audible air velocity.
Configuration item | Representative application parameter |
Blower | 1,000-1,800 m³/h at 3.5-5.0 kPa |
Duct | large smooth bore and long-radius bends |
Room | make-up air and heat rejection |
Control | VFD, current and temperature checks |
Customer value: The audience stays quiet while technicians retain service access.
The case parameters are a starting envelope. During prototype validation, check the shape at the highest and most remote zones, measure internal pressure where possible, record motor current after warm-up and confirm that the intake, discharge and electrical connections remain accessible.
Engineering and Selection Notes
· Treat the inflatable, connecting duct and blower as one air system. A high free-air number alone does not guarantee adequate pressure after bends, filters, valves, long hoses or restrictive inlets.
· Check 50 Hz and 60 Hz performance separately. Motor speed, airflow, static pressure, current and temperature rise can change with frequency and supply voltage.
· Allow an altitude and hot-weather margin. Lower air density reduces mass flow and cooling capacity, so elevated or hot installations may require derating or a larger blower.
· For outdoor use, distinguish weather-resistant construction from fully waterproof construction. Keep connections above standing water, use locally suitable ground-fault protection and inspect cords before deployment.
· Confirm the continuous-duty rating, thermal protection and allowable outlet temperature whenever the blower will run for long periods.
· A remote blower room requires make-up air and heat rejection. A depressurized or hot room reduces delivered performance.
Available Customization
0.75-3.0 kW • 2.4-5.0 kPa class • multi-speed or VFD • portable or skid frame • metal / polymer housing • pressure sensor • weather package • duty/standby manifold
For OEM programs, available work can include outlet matching, housing or base layout, cable and plug selection, switch and speed-control design, labeling, packaging, service parts, sample approval and production test planning. Compliance documents must be tied to the exact final configuration.
NEXT STEP Send the inflatable dimensions, material, inlet size, duct route, voltage/frequency, operating hours, environment and target behavior. We will recommend a pressure-flow envelope and installation architecture before confirming the final model. |
Design responsibility note: blower sizing must be validated as part of the complete inflatable system. For occupied, ride-on, rescue, tent or other safety-critical inflatables, the finished product must also follow the applicable local product, electrical, anchoring, fire and operational requirements.