Fenigal Btcoops - Specialized Balloon Light, Inflatables, Electricals, Equipment and Tools
Fenigal Btcoops - Specialized Balloon Light, Inflatables, Electricals, Equipment and Tools
Translate this website

Google Translate is loaded only when you open this panel, reducing unnecessary requests and layout work during the first page load.

Loading language options…
Request Quote

Inflatable Fans and Blowers

Professional Product Detail

Chassis Blowers for Columns and Air Dancers | Inflatable Air System Solutions

Choose pressure chassis for upright columns and axial bases for active dancing motion. Typical performance, installation, customer value, application cases and OEM options are included.

Category: Inflatable Fans and Blowers

F&B-20

SERIES 2 - CHASSIS COLUMN AND AXIAL BLOWER BASES

Chassis Blowers for Columns and Air Dancers

Integrated bases that turn airflow, structure, mobility and lighting into one product.

Chassis Blowers for Columns and Air Dancers focuses on integrated bases for inflatable columns, tube dancers, visual display tubes and mobile promotional installations. It uses compact vortex / centrifugal chassis for pressure-sensitive columns and axial bases for high-volume dancing motion to match the airflow behavior to the product rather than forcing one generic fan across unrelated inflatable forms. Choose pressure chassis for upright columns and axial bases for active dancing motion.

The core website envelope is approximately 100-750 W for pressure chassis; 0.5-1.5 HP for axial dancer bases, 100-550 m³/h for pressure chassis; 3,500-10,000 m³/h for axial bases and 0.5-1.9 kPa for pressure chassis; low-static open-volume duty for axial bases. These numbers are presented as a selection range, not as a guaranteed model. The final duty point must be confirmed after voltage, frequency, altitude, ambient temperature, duct geometry, fabric leakage and operating hours are known.

Product and Engineering Snapshot

Selection item

Typical specification / content

Product positioning

integrated bases for inflatable columns, tube dancers, visual display tubes and mobile promotional installations

Air technology

compact vortex / centrifugal chassis for pressure-sensitive columns and axial bases for high-volume dancing motion

Typical power

100-750 W for pressure chassis; 0.5-1.5 HP for axial dancer bases

Typical airflow

100-550 m³/h for pressure chassis; 3,500-10,000 m³/h for axial bases

Typical static pressure

0.5-1.9 kPa for pressure chassis; low-static open-volume duty for axial bases

Installation forms

weighted or wheeled base, integrated light base, direct fabric collar or multi-outlet chassis

Special functions

sealed / weather-resistant motor options, LED light, casters, handles, multi-speed switch and 9 / 12 / 18 inch class outlets

Parameter note: all values are representative engineering envelopes, not a promise for every model. Final selection must be confirmed against the performance curve at the actual voltage, frequency, altitude, ambient temperature, duct length, outlet geometry and required operating pressure.

Product Positioning and Customer Value

Choose pressure chassis for upright columns and axial bases for active dancing motion. The solution should solve a visible operating problem: soft or unstable fabric, slow recovery, excessive noise, awkward installation, repeated overheating, too many incompatible spare parts, or long deployment time.

Value 1. Matches the airflow technology to either upright shape or animated movement.

Value 2. Combines outlet, stability, mobility, lighting and controls in one deployable module.

Value 3. Reduces setup errors through a direct fabric collar and standardized chassis.

Application-specific integration. Choose pressure chassis for upright columns and axial bases for active dancing motion. This creates a clearer path from the inflatable requirement to a serviceable product package.

Where This Page Creates Value

Representative use patterns include Inflatable column, Single-leg dancer, Two-leg figure, Retail roadside and Event décor. Each application changes the balance between airflow, static pressure, noise, installation space and service access. For this reason, the application list should be used as a routing guide: the final blower recommendation follows the actual inlet, duct and prototype pressure behavior.

· Inflatable column: compact integrated pressure base. The selection should be confirmed against the complete installed resistance and duty.

· Single-leg dancer: 9, 12 or 18 inch class outlet. The selection should be confirmed against the complete installed resistance and duty.

· Two-leg figure: two synchronized bases or engineered dual outlet. The selection should be confirmed against the complete installed resistance and duty.

· Retail roadside: weather-aware high-volume base. The selection should be confirmed against the complete installed resistance and duty.

· Event décor: integrated LED and premium finish. The selection should be confirmed against the complete installed resistance and duty.

Representative Application Case

A promotion company rents 2 m light columns, 6 m dancers and 3 m branded columns.

A promotion company rents 2 m light columns, 6 m dancers and 3 m branded columns. The case is intentionally representative rather than tied to an original equipment source. It shows how the product page can translate a customer scenario into a practical engineering recommendation.

Challenge: One base type gives weak movement in dancers and excessive motion in columns.

Configuration item

Representative application parameter

Base A

150-400 W vortex chassis

Base B

450-750 W pressure chassis

Base C

0.75-1.0 HP axial base

Base D

1.0-1.5 HP axial base

Common

handles, casters, cables and optional LED

Customer value: The fleet gets the right motion or shape while keeping operator interfaces consistent.

The case parameters are a starting envelope. During prototype validation, check the shape at the highest and most remote zones, measure internal pressure where possible, record motor current after warm-up and confirm that the intake, discharge and electrical connections remain accessible.

Engineering and Selection Notes

· Treat the inflatable, connecting duct and blower as one air system. A high free-air number alone does not guarantee adequate pressure after bends, filters, valves, long hoses or restrictive inlets.

· Check 50 Hz and 60 Hz performance separately. Motor speed, airflow, static pressure, current and temperature rise can change with frequency and supply voltage.

· Allow an altitude and hot-weather margin. Lower air density reduces mass flow and cooling capacity, so elevated or hot installations may require derating or a larger blower.

· For outdoor use, distinguish weather-resistant construction from fully waterproof construction. Keep connections above standing water, use locally suitable ground-fault protection and inspect cords before deployment.

· Confirm the continuous-duty rating, thermal protection and allowable outlet temperature whenever the blower will run for long periods.

· Base stability and fabric attachment must be considered independently from airflow; casters should be secured during operation.

Available Customization

9 / 12 / 18 inch outlet • custom base size • integrated LED • caster and handle • single or multi-speed • protected motor option • custom color • flight case

For OEM programs, available work can include outlet matching, housing or base layout, cable and plug selection, switch and speed-control design, labeling, packaging, service parts, sample approval and production test planning. Compliance documents must be tied to the exact final configuration.

NEXT STEP  Send the inflatable dimensions, material, inlet size, duct route, voltage/frequency, operating hours, environment and target behavior. We will recommend a pressure-flow envelope and installation architecture before confirming the final model.

Design responsibility note: blower sizing must be validated as part of the complete inflatable system. For occupied, ride-on, rescue, tent or other safety-critical inflatables, the finished product must also follow the applicable local product, electrical, anchoring, fire and operational requirements.


Project Inquiry · Technical & Commercial

Send Your Custom Product Requirement

Tell us the product family, intended application, size, quantity, operating conditions and delivery target. Your inquiry email will automatically include the page you are viewing so our team can understand the exact product, technology or reference that led to your request.

  • Product family or model of interest
  • Required size, quantity and customization
  • Application, installation and operating environment
  • Project country, operating conditions and delivery target
Inquiry context Current page details will be attached automatically.